Minimum subfloor thickness 23 32 3 4 nom.
Ditra heat cable spacing.
The minimum spacing is as follows.
Mark the sensor location on the ditra heat and cut the matting to recess the sensor.
Heating cable cold splice installation.
What is the minimum stud spacing when installing the schluter ditra heat e hk heating cables.
But remember that cables should not be underneath a vanity.
Buffer zones are helpful because it s hard to know exactly where the heating cable will end.
Cables should also not be run underneath any cabinets or furniture.
Do not purchase a heating cable the same size as the area to be.
In the case of wall installation the heating cables are installed once an adequate adhesive bond has been reached.
See the ditra heat installation handbook for more information.
2 inches from toilet flanges you ll melt the was ring if closer 6 inches from floor drains.
Keep in mind that ditra heat cables should not be underneath a vanity.
Do not cut or modify the cable in any way as this may change the cable resistance.
A two stud spacing is used when connecting the 240 v cable to a 208 v power supply.
Baseboard heaters forced air vents fireplaces etc schluter recommends adding a buffer zone to your floor plan.
19 mm tongue and groove with 1 8 3 mm gap between sheets.
Minimum 2 x 2 50 mm x 50 mm tile for natural stone see detail dh w s page 4 requirements.
In floor areas the heating cables can be installed immediately after adhering schlüter ditra heat matting with a minimum spacing of 9 cm every third stud 136 w m.
Install the thermostat sensors evenly spaced between two cable runs at a distance of at least 24 from the wall.
Walls or fixtures 3 75 mm heat sources baseboard heaters fireplaces forced air heating ducts etc 8 200 mm floor drains 6 150 mm select a heating cable close to but not more than the amount determined in step 3 below.
Minimum spacing from centerline of toilet drains is 7 180 mm.
The minimum spacing is as follows 2 inches from walls partitions and fixed cabinets2 inches from toilet flanges you ll melt the was ring if closer 6 inches from floor drains8 inches from heat sources e g.
It is recommended to temporarily remove the heating cable from the area while cutting the matting.
Ditra heat cable 37 5 sq ft 120 volts the cable is specifically designed to be used with the ditra heat sheets.
Minimum spacing from other heat sources baseboard heaters fireplaces forced air heating ducts etc is 8 200 mm minimum spacing from any plumbing drain is 4 100 mm.
The allowable heated area is limited by the minimum required spacing from fixed elements such as.
Maximum spacing of joists i joists or floor trusses is 19 2 488 mm o c.
3 1 4 inch spacing should be left between cable runs as narrower spacing may cause fire or damage to the floor covering and wider spacing may result in insufficient power to warm the floor.
This practice may be desirable to increase heat output e g over uninsulated on or below grade concrete subfloors or to consume more cable length in a given area e g when using the standard 3 stud spacing.
However cable may also be spaced at continuously alternating 3 stud 2 stud intervals in isolated areas or over the entire floor.
Heating cables are limited to a minimum space of 2 from walls partitions and fixed cabinets 8 from any heat source and 4 from plumbing drains.