Getting back onto the wheelchair is a different matter.
Disabled wc door width.
Direction width of approach new buildings mm existing buildings mm straight on without a turn 800 750 at right angles to an access route at least 1500mm wide 800 750 at right angles to an access route at least 1200mm wide 825 775 external doors to buildings used by the general public 1000 775 note.
These are of course just the minimum requirements.
Due to the width of many wheelchairs it can be difficult to find a wheelchair accessible door.
The door of the compartment that contains the toilet facilities shall open outwards unless a 1 2 m diameter area that is clear of all fittings fixtures and the line of the door swing is provided.
Our own disabled toilet door range is 926mm wide and can be seen at dda toilet doors locks signs.
Unlike doors in dwellings the clear opening width with regards to doors to non dwellings is measured up to any projecting door item including furniture weather boards etc.
The height is no different from a normal door.
According to document m of the uk building regulations access to and use of buildings other than dwellings wheelchair users should be able to comfortably approach transfer to and use the sanitary facilities.
The width of a disabled toilet door should be at least 900mm and open outward rather than inward.
The seat of a standard wheelchair is approximately 480mm above floor level.
It shall be fitted with a grab rail on the inside and an easy to use locking device.
Effective clear width of doors 25 10.
Despite this dda compliance is still the way many people refer to accessibility regarding doors.
These doors are plenty wide enough but also offer the added benefits of strength durability and fantastic looks.
It s important to note that although referred to as dda compliant the disability discrimination act or dda is no longer in effect.
Key dimensions associated with passenger lifts 34 note.
What size should a disabled toilet door be.
A space of at least 300mm is generally required next to the leading edge.
Diagram 12 has been moved to approved document k section 1 all other numbering remains the same 13.
The door leaf shall be openable from the outside by the use of a suitable device in the case of an emergency and such leaf shall be fitted with a suitable means of indicating whether the compartment is occupied.
The question of what size the modern disabled toilet room within a commercial use building should be is a common one.
The following article sets out to explore the required dimensions.
However doors are permitted to open beyond 900 to reduce the impact of projecting elements.
Compulsory dimensions for a disabled toilet state that the room needs to be at least 2200mm in length and 1500mm in width.
To overcome this issue we have a range of doors that are wider than 33 inches or 838mm.
The ecw is the width of the opening measured at right angles to the wall in which the door is situated from the outside of the door stop on the closing side to any obstruction on the.
It may be possible to slide off of the wheelchair and drop onto the toilet seat.
An example of wheelchair spaces in a lecture theatre 39 14.
What are dda compliant door widths is a question that we re often asked.
Dimensions larger than these will give a wheelchair user a larger turning circle providing greater comfort.
Possible location of wheelchair spaces in front of a rear aisle 41 15.